Polyester TPU Films and Coatings: Diagnosing Hydrolysis After Humid Exposure
Introduction A coated textile can pass peel testing before shipment and delaminate after warm, humid storage. A TPU film may become tacky or tear sooner after a similar exposure. The first step is to locate the failure within the film, coating, adhesive or substrate. This guide focuses on diagnosing the finished construction and qualifying a formulation against that failure. Where hydrolysis occurs in polyester TPU The representative bond in the diagram lies in the polyester soft segment. Water-driven ester cleavage creates carboxyl and hydroxyl ends and can undermine mechanical retention. Confirm the soft-segment chemistry with the resin supplier. Check for